Impact Of Time And Temperature On The Dimensional Stability Of Alginate Impressions: A Comparative In Vitro Analysis
Main Article Content
Abstract
Objective: This in vitro study aimed to evaluate the dimensional stability and shrinkage behavior of three commercially available alginate dental impression materials (Velplast, Marieflex, and Zelgan) under varying pouring times and storage temperatures.
Materials and Methods: A total of 90 impressions were made using Velplast, Marieflex, and Zelgan. Impressions were divided into three groups based on pouring times: immediate, 20 minutes, and 40 minutes. Additionally, impressions were stored at three different temperatures: 25°C, 30°C, and 40°C. Dimensional changes and shrinkage were measured using a traveling microscope, and statistical analysis was performed using p-values to assess significance.
Results: The study found that increased delay in pouring and elevated storage temperatures led to significant dimensional changes in all materials. Velplast exhibited minimal shrinkage at 25°C (0.10%) but showed the highest shrinkage at 40°C (-0.30%). Marieflex and Zelgan similarly demonstrated lower shrinkage at 25°C, but their shrinkage increased to -0.25% and -0.28%, respectively, at 40°C. Immediate pouring resulted in the highest dimensional stability, with accuracy rates of 99.5%, 99.7%, and 99.3% for Velplast, Marieflex, and Zelgan, respectively.
Delayed pouring led to greater dimensional distortion, particularly at 40 minutes.
Conclusion: The dimensional stability of alginate impression materials is significantly influenced by both pouring time and storage temperature. Immediate pouring is recommended to maintain accuracy, and elevated temperatures should be avoided to minimize shrinkage. Marieflex showed the highest stability across all conditions, making it a suitable option for clinical cases requiring delayed pouring.
Article Details
References
Nallamuthu N, Braden M, Patel MP. Dimensional changes of alginate dental impression materials. Journal of Materials Science: Materials in Medicine. 2006 Dec;17:1205-10.
Penfold RD, Brandt WC, Miranda ME, Vitti RP. Evaluation of dimensional stability and details reproduction of alginate molds storage in different times and temperature [Avaliação da estabilidade dimensional e reprodução de detalhes de moldes de alginatos armazenados por diferentes tempos e temperatura]. Brazilian Dental Science. 2018. Jan/Mar;21(1):37-43
Kulkarni MM, Thombare RU. Dimensional changes of alginate dental impression materials-an invitro study. Journal of clinical and diagnostic research: JCDR. 2015 Aug;9(8):ZC98.
Todd JA, Oesterle LJ, Newman SM, Shellhart WC. Dimensional changes of extendedpour alginate impression materials. Am J Orthod Dentofacial Orthop. 2013 Apr;143(4 Suppl):S55-63. doi: 10.1016/j.ajodo.2012.06.016.
Shafiq U, Rahim S, Saleem A, Anwari M. Effect of pouring time on the dimensional stability of alginate impression material. Pakistan Oral & Dental Journal. 2016 Sep 30;36(3):495-97.
Nandini VV, Venkatesh KV, Nair KC. Alginate impressions: A practical perspective. J Conserv Dent. 2008; 11(1): 37-41.
Nassar U, Aziz T, Flores-Mir C. Dimensional stability of irreversible hydrocolloid impression materials as a function of pouring time: a systematic review. J Prosthet Dent. 2011; 06(2): 126-33.
Sayed ME, Gangadharappa P. Three-dimensional evaluation of extended pour alginate impression materials following variable storage time intervals and conditions. Indian journal of dental research. 2018 Jul 1;29(4):477-86.
Gumus HO‚ Dincel M, Buyuk SK, Kilinc HL, Bilgin MS, Zortuk M. The effect of pouring time on the dimensional stability of casts made from conventional and extended pour irreversible hydrocolloids by 3D modeling. J Dent Sci 2015;10:275 81.
Walker MP, Burckhard J, Mitts DA, Williams KB. Dimensional change over time of extended storage alginate impression materials. Angle Orthod 2010;80:1110 5.
Shaba OP, Adegbulugbe IC, Oderinu OH. Dimensional stability of alginate impression material over a four hours time frame. Nig Q J Hosp Med. 2007; 17(1): 1-4.
Farzin M, Panahandeh H. Effect of pouring time and storage temperature on dimensional stability of casts made from irreversible hydrocolloid. J Dent (Tehran) 2010;7:179 84.
Fellows CM, Thomas GA. Determination of bound and unbound water in dental alginate irreversible hydrocolloid by nuclear magnetic resonance spectroscopy. Dent Mater 2009;25:486 93.
Rohanian A, Shabestari GO, Zeighami S, Samadi MJ, Shamshiri AR. Effect of storage time of extended-pour and conventional alginate impressions on dimensional accuracy of casts. J Dent (Tehran). 2014 Nov;11(6):655-64.
Wadhwa SS, Mehta R, Duggal N, Vasudeva K. The effect of pouring time on the dimensional accuracy of casts made from different irreversible hydrocolloid impression materials. Contemp Clin Dent. 2013 Jul;4(3):313-8.
Nassar U, Hussein B, Oko A, Carey JP, Flores Mir C. imensional accuracy of 2 irreversible hydrocolloid alternative impression materials with immediate and delayed pouring. J Can Dent Assoc 2012;78:c2
Farzin M, Panahandeh H. Effect of pouring time and storage temperature on dimensional stability of casts made from irreversible hydrocolloid. J Dent (Tehran) 2010;7:179 84.
Rodrigues SB, Augusto CR, Leitune VC, Samuel SM, Collares FM. Influence of delayed pouring on irreversible hydrocolloid properties. Braz Oral Res 2012;26:404 9.
Schleier PE, Gardner FM, Nelson SK, Pashley DH. The effect of storage time on the accuracy and dimensional stability of reversible hydrocolloid impression material. J Prosthet Dent 2001;86:244 50.
Erbe C, Ruf S, Wöstmann B, Balkenhol M. Dimensional stability of contemporary irreversible hydrocolloids: Humidor versus wet tissue storage. J Prosthet Dent 2012;108:11422.